P1 Terminal Block Hook-Up Diagram
DP4
* P1-8 & P1-9 signal inputs may be programmed for a number of functions.
P1 Terminal Block Descriptions
P1-1 (AC / N) – For single phase AC lines connect the Neutral side of your AC line to this terminal.
For systems with two hot AC lines, connect either of the Hot AC lines to this terminal.
P1-2 (AC / L) – For single phase AC lines connect the Hot side of your AC line to this terminal. For
systems with two hot AC lines, connect either of the Hot AC lines to this terminal.
P1-3 (HI) - This is the POT HI reference terminal. This terminal must be connected to the most positive
speed pot input terminal of the partner control. This terminal will generally be referred to as Pot
HI or +V for positive supplies and Com for negative supplies.
P1-4 (WP) - This is the Wiper output terminal. This terminal will output an analog voltage signal
proportional to the referenced voltage signals connected to P1-3 (HI) and P1-5 (LO). This
terminal should be connected to the wiper or signal input of the partner control.
P1-5 (LO) - This is the POT LO reference terminal. This terminal must be connected to the most
negative speed pot input terminal of the partner control. This terminal will generally be referred
to as Pot LO or Com for positive supplies and –V for negative supplies.
P1-6 (COM) – This is the common point for the control logic. Any other equipment or source needing
to reference the control common will be connected to this terminal.
P1-7 (+5V) – This is a self-contained +5VDC power supply capable of up to 50mA. Various low-
voltage sensors can be driven from this supply if desired.
P1-8 (S1) – This is the programmable signal 1 input. It can be confi gured to perform a number of
special features including inhibit and jog.
P1-9 (S2) – This is the programmable signal 2 input. It can be confi gured to perform a number of
special features including inhibit and jog.
P1-10 (1NO) – This is the normally-open contact of the user assignable relay output.
P1-11 (1C) – This is the common contact of the user assignable relay.
P1-12 (1NC) – This is the normally-closed contact of the user assignable relay output.
Installation & Diagrams
N
P1-1
L
P1-2
HI
P1-3
W
P1-4
LO
P1-5
COM
P1-6
COMMON
+5V
P1-7
S1
P1-8
S2
P1-9
NO
Alarm Output - Normally Open
P1-10
C
Alarm Output - Common
P1-11
NC
Alarm Output - Normally Closed
P1-12
5
}
AC INPUT
2 AMP
AC INPUT
HIGH OUTPUT
WIPER OUTPUT
LOW OUTPUT
}
+5VDC
*
SIGNAL 1
*
SIGNAL 2
}
Form C
Relay output
(Programmable)
85-265VAC
}
Connect to the speedpot
of the control being driven.
High must be positive
voltage with respect to low.
External Supply (+5V@50mA)