Water Connections; Drain Connections - Champion IUH 351 Instalación Y Operación, Manual De Servicio Y Partes De Reemplazo

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Water Connections

NOTE
Plumbing connections must comply with local plumbing and sanitary codes.
IMPORTANT
Make sure that the flexible water supply and drain hoses are not kinked.
All models have a 6 ft. flexible hot water fill hose with a 3/4" NPS connector.
1.
A 1/2" or larger main incoming supply line should be installed to the dishwasher.
2.
A 1/2" or larger shut-off valve should be installed in the water supply line as close to the
3.
dishwasher as possible for service.
4.
The pressure regulating valve, PRV, must be installed after the shut-off service valve if the
incoming flow pressure exceeds
20-22 psi.
The hot water supply must provide a minimum of 140°F/60°C, measured at the dishwasher for
5.
the 40°F/ 22°C rise booster.
A water hardness of 3 grains/U.S. gal[51.3 mg/L] or less is recommended.
6.

Drain Connections

The dishwasher has a 6 ft. flexible hot water fill hose with a 3/4" NPS connector.
1.
2.
The machine is a gravity drain.
The maximum drain flow is 8 U.S. gpm /30 LPM.
3.
4.
Make sure the drain hose does not kink. Kinks will prevent the dishwasher from draining
completely causing water to flow out the front door.