Loading the power pack
Note: The final limit stop jacking screw
should only be used if the final limit is not
being recognised when the pack is run on the
track. Tighten one full turn max after contact
(Figure 28).
Slide Track installations
14 When loading the pack take care to correctly
position the two busbar pickup loading tools
(Figure 29).
15 In order to load the pack dipswitch 2 on the
main PCB must be set to the OFF position.
Once loaded this dipswitch should be
returned to the ON position to enable the
Slide Track (see wiring diagrams).
Note: Do not drive the power pack in the UP
direction until the top end cap has been fitted.
The busbar may move and lose contact with
the spring at the bottom of the track.
16 Connect the power supply to the ring main or
fused spur. A 400mm long "lazy loop" must
be left by the stringer near the point under
the centre of the track where the power cable
enters the track. This is to allow slack for the
Slide Track's travel (Figure 30).
17 Connect the top track safety edge assembly
(active end cap) remembering to attach the
additional wires (Figure 31).