TECHNICAL DATA

VEC with a 3-row coil
Mod.
Heating
Heating capacity
Electric heater heating capacity
Cooling
Total cooling capacity
Sensible cooling capacity
Water flow rate
Water pressure drops
Air flow rate
Number of fans
 Sound power
Sound power
Water content
Max. motor power
Max. input current
Max. motor power
with electric heater
Input current
with electric heater
3R coil connections
1R coil connections
Power supply
Performance values refer to the following conditions:
 Sound pressure measured in semi-reverberating chamber, 85m
and with reverberation time Tr = 0.5s.
Cooling:
- room air temperature 27°C D.B., 19°C W.B.;
• maximum speed:
- water inlet temperature 7°C; ∆t water 5°C.
• medium and minimum speed:
- water inlet temperature 7°C;
- water flow rate as at maximum speed.
OPERATING ENVIRONMENT
The units are designed for installation in closed environments in conditions
of 'urban', non-marine atmosphere with non-corrosive and non-dusty
characteristics.
Under no circumstances the following concentrations of pollutants in the air, in
which the unit must operate, shall be exceeded:
SO
<0,02 ppm
2
H
S
<0,02 ppm
2
NO,NO
<1 ppm
2
NH
<6 ppm
3
N
O
<0,25 ppm
2
The unit should not be installed in locations characterized by the presence of
flammable gases or acidic or alkaline substances.
Otherwise the coils and the internal components of the equipment could suffer
serious and irreparable damage from corrosion.
W (max.)
W (med.)
W (min.)
W
W (max.)
W (med.)
W (min.)
W (max.)
W (med.)
W (min.)
l/h
kPa
3
m
/h (max.)
3
m
/h (med.)
3
m
/h (min.)
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)
dB (A) (max.)
dB (A) (med.)
dB (A) (min.)
l
W
A
W
A
ø
ø
VEC 20
VEC 30
1835
2770
1505
2340
1105
1950
950
1300
1320
1950
1085
1645
805
1370
1085
1535
885
1285
640
1055
227
335
4,6
13,3
247
383
194
309
130
241
1
2
39,5
36,5
33,5
31,5
26,5
26,5
48,0
45,0
42,0
40,0
35,0
35,0
0,79
1,11
25
44
0,12
0,21
975
1344
4,25
5,86
1/2"
1/2"
1/2"
1/2"
230V ~ 50Hz
3
,
Heating:
room air temperature 20°C D.B.;
• maximum speed:
- water inlet temperature 50°C; ∆t water 10°C.
- water flow rate as for cooling operation.
• medium and minimum speed:
- water inlet temperature 50°C;
- water flow rate as at maximum speed.
WARNINGS FOR THE QUALITY OF THE WATER CIRCULATING
IN THE COILS
It is recommended to perform an analysis of the water circulating in the coil
focusing on the research of the possible presence of bacteria (detection of iron
bacteria and micro-organisms that can produce H2S or chemically reduce
sulphates) and on the chemical composition of the water, to prevent corrosion
and fouling inside the tubes.
The water circuit must be supplied and replenished with treated water that does
not exceed the threshold levels indicated below.
Total hardness in mmol/l
-
Chlorides [CL
]
2-
Sulphates [SO
]
4
-
Nitrates [NO
]
3
Dissolved iron
Dissolved oxygen
Carbon dioxide [CO
]
2
Resistivity
pH
IVECLJ 1712 - 5074550_05
VEC 40
VEC 50
3745
4285
3105
3785
2505
2840
1650
1950
2985
3610
2470
3170
1985
2350
2410
2595
1980
2275
1580
1680
514
621
11,3
14,8
511
613
406
529
306
371
2
2
40,0
44,5
34,5
41,5
29,5
34,5
48,5
53,0
43,0
50,0
38,0
43,0
1,48
1,48
57
67
0,28
0,35
1707
2017
7,45
8,83
3/4"
3/4"
1/2"
1/2"
l < mmoll/l < 1,5
< 10 mg/litre
< 30 mg/litre
= 0 mg/litre
< 0,5 mg/litre
4 < [O
] < 9 mg/litre
2
< 30 mg/litre
20 Ohm∙m < Resistivity< 50 Ohm∙m
6,9 < pH < 8
11