Make sure that air comes back from the adjacent rooms to the room where the insert is installed ("return"
-
circuit). Also check that the hot air function does not affect the home ventilation system.
It is important to make sure, while insert working, that the convection air comes in through the intake ports and
comes out through all the outlet vents. If it is not the case, reduce the section of the outlet which works properly
until the other outlets blow hot air : the use of adjustable nozzles makes this balancing easier.
The obturating plate, fitted over the front air outlet, can be adjusted in order to regulate the hot air flow of the
different outlets ; however, this plate maintains a 10 mm "safety" air flow : this prevents overheating of the
appliance when none of the 4 nozzles Ø 125 is open.
5.8.5 Blower electrical connection
-
The appliance is delivered with a flexible cable of an approximate length of 1.5m, allowing it to be connected
to the electricity supply network. The end of the cable is situated at the bottom of the left-hand rear part of
your insert and you will have to pull it (without forcing) to take it out. On the fixed installation, set up an
omnipolar partition device with an opening distance of contacts of at least 3 mm : this device will enable you
to isolate the appliance from the electrical supply network. The installation should be in accordance with the
French standard NFC 15100, and in particular the earth (green and yellow wire) should be connected.
The rated power of the blower is 40 W – incoming voltage 230 V.
-
It might be necessary to remove the ventilator or the fireplace : for this purpose keep a sufficient length of
-
cable so that these operations may be carried out without pulling on the cable.
5.8.6 Final fitting of the turbo insert
Once your turbo insert is in its right position, replace all cast iron parts previously removed, successively the
deflector, plates, combustion grate and door.
5.8.7 Adjusting of the thermostat
Adjusting is factory-set. However we recommend checking it before first lighting. For this operation, open ashpan
door and remove ashpan.
For a 20° C room temperature, when the control lever is set on 0, the gap between the supporting plate and the
flap must be zero (cold appliance) (Fig. 14).
However the flap must be subjected to no thrust, it must lift from its supporting plate when the knob is set to
position 1.
If required, change the flap adjustment by acting upon the adjustment knob : access inside the ashpan
compartment.
NOTA : With use, it may become difficult to turn the thermostat knob
(graphite grease, motor oil) (refer to arrows on Fig. 15).
6 - USE OF YOUR DEVILLE INSERT
Your "closed hearth" is an extremely efficient heating appliance :
High output, slow burning, adjustable output by thermostatic regulation.
6.1 FIRST LIGHTING
-
When the fireplace is completed and the appliance in place, give the various building materials time to dry :
connection and seals on the smoke pipe, stones, hood, etc...
Generally count 2 to 3 weeks for drying.
After lighting the insert for the first time (see § 6.4.1), build a moderate fire for the first few hours using just one
-
log with a diameter of about 15 cm, with the thermostat set on position 4 : this will ensure that the temperature of
all the parts of the fireplace increases gradually and that the appliance will expand normally.
You may find that initially the insert gives off a smell of paint, in which case simply air the room.
-
23
. In that case, oil the control screw