Faulty Fuse wires
• LED "Power On" is flashing
• LED 'BAT' is on
• Faulty fuse wires
•
Check battery connections
•
Check the status of the fuse box
Sulphation boost (1 hr max)
• LED "Power On" is on
• LED "Boost" is flashing
• LED "Temp" is flashing
• LED 'BAT' is flashing
• LED "Fuse" is flashing
Equalization phase on Position 09
Sulphation Float
• LED "Power On" is on
• LED "Float" is flashing
• LED "Temp" is flashing
• LED 'BAT' is flashing
• LED "Fuse" is flashing
• Floating phase on position 09
Manual Equalization
• LED "Power On" is on
• LED "Boost" is flashing
• Holding down the button on the front for 2 seconds will
begin an extra equalization phase.
• The short anti cycle lasts for 24 hrs
• Please note that holding down the "mode" button will
confirm and begin the desulphation programme
Cycle Number
0, 1, 2, 3
4, 5, 6
7, 8
9
Remote
control
Temp sensor
Lenght of equalization phase
2 hours
1 hour
/
Begins programme 9
Connection
Charge
selection
Battery fuses
-DC
+DC1
Page 7
+DC2
+DC3
POWER.ON
Fuse
POWER.ON
BOOST
POWER.ON
FLOAT
MODE
POWER.ON
BOOST
N
L1