5.6 LEVELLING THE STOVE
The stove is supplied with wheels that facilitate its
be level, with the help of a spirit level and moving
wheels are raised off the ground.
A = Spirit Level
5.7 SYSTEM CONNECTIONS
5.7.1 Electrical connection
The stove is connected to the electrical system
simply using the plug supplied.
The electrical connection (plug) must be easily
accessible when the stove is installed.
If the power cord is damaged it must be replaced
to prevent any kind of risk.
5.7.1.1 Earth
residual current circuit-breaker in accordance with
legislation in force (Fig. 5.11).
5.7.2 Attachment to the connection box
The connection box allows communication with the
stove through your mobile device, downloading
the appropriate App.
Attach the connection box to the RJ11 connector
Follow the instructions in the packaging for
commissioning of the device.
5.8 HYDRAULIC SYSTEM
Connection to the hydraulic system and of the
personnel in compliance with the laws and
regulations in force in the country of use.
1. Perform the hydraulic connections to the
stove as shown in the following data sheet in
the Product Manual.
2. Ensure that all the control and safety parts
have been correctly installed including those
supplied data (safety and thermal exhaust
valves).
MAXIMUM OPERATING PRESSURE: 2.5 bar
Systems that completely close the heating system
(zone valves) MUST NOT be inserted into the
unit. For safety reasons, the pump must ALWAYS
be operational when the stove is operational,
evacuating the heat produced.