6
INSTALLATION
in compliance with EN 10683.
6.1
LEVELLING THE STOVE
The stove must be levelled by adjusting the feet
(where featured), then checked using a spirit level
(Fig. 5.10).
A B = Spirit level
6.2
SYSTEM CONNECTIONS
6.2.1 Electrical connection
The stove is connected to the electrical system
simply using the plug supplied (Fig. 5.11).
The electrical connection (plug) must be easily
accessible when the stove is installed.
If the power cord is damaged it must be replaced
to prevent any kind of risk.
6.2.1.1 Earth
residual current circuit-breaker in accordance with
legislation in force.
6.2.2 Connection to an external timer thermostat
The stove can be connected to an external timer
thermostat that switches the stove on or off
according to the set temperature.
When the set temperature is reached the thermostat
opens the circuit and consequently switches off the
stove.
The external thermostat is connected to the two terminals on the rear of the stove, which are jumpered in the
factory. Disconnect the jumper and connect the two thermostat contacts.
is in "call" status. This operation is also required in the event of power failures or if the stove is switched off
manually.
To avoid overlapping the working time bands, it's recommend to disable (set to OFF) the stove's timer.
6.2.3 Operation with room probe
In certain circumstances the stove may need to modulate operation based on the temperature read by the room
6.2.4 Connection to a storage tank with coil
storage tank.
6.2.5 Connection to a storage tank without coil
The stove can be used to maintain the temperature inside a storage tank without coil.
storage tank.
INSTALLATION
1
2 following the instructions shown in paragraph 6.3.
4 following the instructions shown in paragraph 6.3.
00 477 6270 - 02/2018
fig. 5.10
fig. 5.11
31