Function and characteristics

2.1

Characteristics

– High data reliability: output data
are checked in the µC for validity
and plausibility.
– Up to 4 positions can be pro-
cessed
– Definable working strokes
– Absolute output signal
– High resolution, repeatability and
linearity
– Insensitive to shock, vibration,
contamination and noise
– Cable length between transducer
and controller up to 1200 m
– Configuration using Step7, COM-
PROFIBUS, WinDP, or other
configuration softwarer
– Protected to IP 67 per IEC 60529
DIP switches for address setting
IP switches for bus termination
LED for operating state indicator
Notch on upper housing side marks start of measuring range
Micropulse transducer
Fig. 2-1: Basic configuration
2.2

Function

The transducer contains a wave-
guide enclosed by an extruded alu-
minum housing. A magnet attached
to the moving member of the ma-
chine is moved across the top of
the housing and its position con-
stantly updated.
The magnet defines the measured
position on the waveguide. An inter-
nally generated INIT pulse interacts
with the magnetic field of the mag-
net to generate a magnetostrictive
torsional wave in the waveguide
which propagates at ultrasonic
speed.
The torsional wave arriving at the
end of the waveguide is absorbed in
the damping zone. The wave arriv-
ing at the beginning of the wave-
guide creates an electrical signal in
the coil surrounding the waveguide.
Nominal stroke =
Measuring range
Moving
member
Current magnet
position
Machine
The propagation time of the wave
is used to determine the position
to a resolution of 5 µm. This takes
place with high precision and re-
peatability at the selected resolu-
tion within the measuring range
indicated as the nominal stroke
length.
On both ends of the nominal
stroke length is an area which pro-
vides an unreliable signal, but
which may be entered.
The electrical connection between
the transducer, the processor/con-
troller and the power supply is via a
cable, which depending on the
version is either fixed or con-
nected using a female connector.
Dimensions for installing the
Micropulse transducer and for the
magnets and control arm are found
on ➥ ➥ ➥ ➥ ➥ pages 4 to 6.