BML-S1F_-A/Q _ _ _ -M_ _ 0- _ 0-...
Incremental Magnetic Linear Encoder
1
Notes to the user
1.1
Validity
This guide describes the construction, function and
installation options for the BML magnetic linear encoder.
It applies to sensor head series
BML-S1F_-A/Q _ _ _ -M_ _ 0- _ 0-KA /KD/KF_ _ and
BML-S1F_-A/Q _ _ _ -M_ _ 0- _ 0-KA_ _-S284
(see Type code breakdown on pages 23 and 24).
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the position
measuring system.
In this guide, a magnetic tape with 1 mm pole
width is representative of all other magnetic
tapes.
1.2
Symbols and conventions
Individual instructions are indicated by a preceding
triangle.
► Instruction 1
Action sequences are numbered consecutively:
1. Instruction 1
2. Instruction 2
Note, tip
This symbol indicates general notes.
1.3
Scope of delivery
–
Sensor head
–
Condensed guide
The magnetic tapes are available in different
versions and must be ordered separately.
www.balluff.com
1.4
Approvals and markings
UL approval
File no.
E227256
The CE Mark verifies that our products
meet the requirements of EU Directive
2004/108/EC (EMC Directive).
The position measuring system meets the requirements of
the following generic standards:
–
EN 61000-6-1 (noise immunity)
–
EN 61000-6-2 (noise immunity)
–
EN 61000-6-3 (emission)
–
EN 61000-6-4 (emission)
and the following product standard:
–
EN 61326-2-3
Emission tests:
–
RF emission
EN 55016-2-3 (industrial and residential areas)
Noise immunity tests:
–
Static electricity (ESD)
EN 61000-4-2
–
Electromagnetic fields (RFI)
EN 61000-4-3
–
Electrical fast transients (burst)
EN 61000-4-4
–
Surge
EN 61000-4-5
–
Conducted interference induced
by high-frequency fields
EN 61000-4-6
–
Magnetic fields
EN 61000-4-8
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
Severity level 3
Severity level 3
Severity level 1
Severity level 2
Severity level 3
Severity level 4
english
5