Startup
5.1
Starting up the system
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is part
of a closed loop system whose parameters have not yet
been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections or devices.
2. Turn on the system.
3. Check measured values in the controller and reset if
necessary.
5.2
Check system function
Check all functions as follows after assembling the position
measuring system or exchanging the sensor head:
1. Switch on the sensor supply voltage.
2. Move the sensor head along the entire measuring
range and check that all signals are output. To do this,
mark the start position, move slowly forward, and then
move back quickly into the start position. Use a
BDD counter or the controller to count the impulses.
The system has been set correctly if the impulses have
the same value as the start value.
3. Check that the count direction corresponds with the
direction of travel.
5.3
Operating notes
–
Check and record the function of the position
measuring system and all associated components on a
regular basis.
–
If there are malfunctions in the position measuring
system, take it out of service and secure it against
unauthorized operation (see also Troubleshooting).
–
Secure the system against unauthorized use.