Conversion Form Ng To Lpg Or From Lpg To Ng - CORBERO CPCG602W Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Procedure:
---Re-ignite the burner and set to MIN.
---Remove the control knob and use a thin bladed screwdriver to turn the adjustment screw until the flame is steady and does not
extinguish, when the knob is turned from MIN to MAX.
---The adjustment screw may be located at the centre of the gas tap control shaft or on the gas tap body, left of the control shaft or below
(see figure 8*).
---Repeat the adjustment procedure for all burners.
Pressure Testing
---Remove left hand pan support and front left burner cap and crown.
---Fit manometer tube over the injector.
---Turn on the burner gas supply and ignite another burner.
---Turn off the burner supplies.

Conversion form NG to LPG or from LPG to NG

Important
The replacement / conversion of the gas hob should only be undertaken by a competent person.
It is important to note that this model is designed for use with which gas category. Please check the note on the appliance. But it can be
converted from one gas category to another providing the correct injectors are fitted and the gas rate is adjusted to suit.
Method
Ensure that the gas taps are in the "
Isolate the hob from the electrical supply
Remove all pan supports, burner caps, rings, crowns and control knobs
With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate injectors.
To adjust the gas rate
With the aid of a thin bladed screwdriver completely tighten down by the pass adjustment screw, which is located down the center of the
gas tap control shaft. Upon completion stick the replacement rating plate on the under side of the hob.
" position
8

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido