The generating sets GE 7000 - 7500 are units which transform the mechanical energy, generated by endothermic engine, into
electric energy, through an alternator.
They are meant for industrial and professional use, powered by an endothermic engine; they are composed of various main parts
such as: engine, alternator, electric and electronic controls, the fairing or a protective structure.
The assembling is made on a steel structure, on which are provided elastic support which must damp the vibrations and also
eliminate sounds which would produce noise.
Technical data
GENERATOR
Three-phase generation (*Stand-by)
Single-phase generation
Single-phase generation
Power factor (Cos ϕ) ϕ) ϕ) ϕ) ϕ) / Duty cycle
Frequency
ALTERNATOR
Type
Insulating class
ENGINE
Type
Output (*Stand-by)
Speed
Displacement
Cylinders
Fuel consumption
Engine oil capacity
GENERAL SPECIFICATIONS
Tank capacity
Running time
Protection
Dimensions / max. Lxwxh (mm) *
Weight
Noise level
* Dimensions and weight are inclusive of all parts without wheels and towbar.
Declared power according to ISO 3046/1 (temperature 25°C, 30% relative hummidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power P.R.P.) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the P.R.P. It's admitted overload of 10% each hour every 12
h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
For possible modifications or changes to be brought on the engines, with climate conditions different from those above
mentioned, please call our Assistance Authorized Centers.
The machine respects the noise limits, expressed in sound power, given in the a.m. directives.
These limits can be used to judge the sound level produced on site.
For example:
the sound power level of 100 LWA.
The sound pressure (noise produced) at 7 meters distance is about 75dBA (the limit value less 25).
To calculate the sound level at other distances use this formula:
ry²
dBAx = dBAy + 10 log
rx²
At 4 meters the noise level becomes: 75 dBA + 10 log
Technical data and machine description
GE 7000 BS/GS
6 kVA (5.4 kW) / 230 V / 26 A
6 kVA (5.4 kW) / 110 V / 54,5 A
0,9 / 100 %
50 Hz
Self-excited, self-regulated, brushless
single-phase, synchronous
H
85 kg
99 LWA (74 dB(A) - 7 m)
ACOUSTIC POWER LEVEL
Gasoline, 4-Stroke, air cooled
Honda GX 390
8,3 kW (11,3 HP)
3000 rpm
389 cm
3
1
313 g/kWh
1,1 l
6,5 l
3 h
IP 23
910x525x613
OUTPUT
= 80 dBA
GE 7000 - 7500 BS/GS
GE 7500 BS/GS
7 kVA (5.6 kW) / 400 V / 10.1 A
4 kVA / 230 V / 17.4 A
-
0,8 / 100 %
50 Hz
Self-excited, self-regulated
three-phase, synchronous
H
88 kg
99 LWA (74 dB(A) - 7 m)
M
51