Blower Feature; Emptying Liquid Waste From Tank; Automatic Suction Shut Off - Shop-Vac SMK Serie El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BLOWER FEATURE

36. Your vacuum can be used as a powerful blower. To use your unit as a blower, unscrew blower port cover located on the backside
of the tank cover. Clear hose of any obstructions or debris. Insert hose end with locking nut into blower port and tighten,
FIGURE 23. do not over-tighten. Caution should be used when using as a blower due to the powerful force of air when using
certain attachments.
FIGURE 23
WARNING:
DEBRIS FROM BEING BLOWN OR RICOCHETING INTO THE EYES OR FACE WHICH CAN
RESULT IN SERIOUS INJURY.
EMPTYING LIQUID WASTE FROM
THE TANK
37. To empty tank, turn unit off and remove plug from the wall receptacle. To empty liquid into floor drain the vacuum is equipped with
easy flow drain. Twist drain cap until liquid starts to flow. Pull drain out keeping opening at the bottom. The further you pull out the
faster the liquid will flow. After the tank is empty, return the drain cap to its original position. To continue use, plug the cord into the
wall receptacle and turn the unit on. Use side carry handles for lifting vac when draining tank into drains that are located above
floor level.
LOCKING CASTERS
38. To lock the caster, step gently or using your hand flip the metal on/off tab to the on position. FIGURE 24. This will lock the caster
in place to prevent movement of the vacuum. To unlock, gently step or using your hand flip the metal on/off tab in opposite
position. FIGURE 25.
FIGURE 24

AUTOMATIC SUCTION SHUT OFF

39. The vacuum is equipped with an automatic suction shut-off that operates when picking up liquids. As the level of the liquid rises in
the tank, an internal float rises until it seats itself against a seal at the intake of the motor, shutting off suction. When this happens,
the motor will develop a higher than normal pitch noise and the suction is drastically reduced. If this occurs, turn unit off
immediately. Failure to turn unit off after float rises and shuts off suction will result in extensive damage to the motor.
NOTE: FOR MAXIMUM PERFORMANCE, WHEN VACUUMING, REMOVE BLOWER
PORT COVER.
ALWAYS WEAR EYE PROTECTION
FIGURE 25
TO PREVENT ROCKS OR
PAGE 9

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Smk-sq6508891411

Tabla de contenido