Fault/Alarm
F0185:
It indicates a fault at the pre-charge
Pre-Charge
contactor.
Contactor Fault
A0210:
Indicates that the drive is in Bypass
Drive in Bypass
mode.
mode
A0211:
Indicates that the drive is in Fire
Drive in Fire Mode
Mode.
F0228:
Refer to the RS-232 / RS-485 Serial Communication Manual.
Serial
Communication
Timeout
A0702:
Refer to the SoftPLC Manual.
Disabled Inverter
A0704:
Two Enabled
Movements
A0706:
Reference not
Programmed for
SoftPLC
F0711:
Fault in the execution of the SoftPLC.
Fault in the
Execution of the
SoftPLC
A0750:
It indicates to the user there is not
Programming AIx for
analog input programmed for Main
Main PID Controller
PID controller feedback.
Feedback
A0752:
It indicates to the user there is not
Programming DIx for
digital input programmed for Main
Main PID Controller
PID controller
Automatic/Manual
Automatic/Manual selection.
Selection
A0754:
It indicates to the user that the origin
Programming Local
of the speed reference in the Local
Reference (P0221)
situation is not programmed for
for SoftPLC
SoftPLC.
A0756:
It indicates to the user that the origin
Programming
of the speed reference in the Remote
Remote Reference
situation is not programmed for
(P0222) for SoftPLC
SoftPLC.
A0758:
It indicates to the user that the
Programming
engineering unit parameters for
Indirect Engineering
motor speed is not programmed for
Unit 4 (P0516) for Hz
Hz or rpm.
or rpm
A0760:
It indicates to the user that the Main
Low Level for Main
PID controller feedback is low.
PID Controller
Feedback
F0761:
It indicates to the user that the Main
Low Level for Main
PID controller feedback is low.
PID Controller
Feedback
Quick Parameter Reference, Faults and Alarms
Description
The digital input programmed for activating the Bypass
mode is active.
The digital input programmed for activating the Fire
Mode is active.
Parameter P0231 or P0236 or P0241 is not
programmed in 5, 6 or 7.
Parameter P0263 or P0264 or P0265 or P0266
or P0267 or P0268 or P0269 or P0270 is not
programmed in 20.
Main PID controller is enabled (P1017 in 1 or 2) and
CFW701 frequency inverter run the motor in Local
situation and parameter P0221 is not programmed in 7.
Main PID controller is enabled (P1017 in 1 or 2) and
CFW701 frequency inverter run the motor in Remote
situation and parameter P0222 is not programmed in 7.
Parameter P0516 is not programmed in 13 (Hz) or 3 (rpm).
Parameter P1030 is programmed in 1 and the Main
PID controller feedback value is remaining below the
value programmed in P1031 for the time programmed
in P1032.
Parameter P1030 is programmed in 2 and the Main
PID controller feedback value is remaining below the
value programmed in P1031 for the time programmed
in P1032.
Possible Causes
Defective pre-charge contactor.
Open command fuse.
Phase loss at the L1/R or L2/S input.
P0355 = 1 (incorrect setting for mechanical models
"E" powered by the DC Link. For these models should
be set P0355 = 0).
Incompatible applicative.
Fault during upload of the applicative.
CFW701| 25