10) Weld the connections of liquid and suction lines
with the Ball Valve body protected from
overheating. Do not let the valve body exceed
150°C and the valve connections 700°C.
Ball Valve
5/8" OD
11) After tubing connections are complete, the
connecting pipework should be leak-tested and
evacuated.
12) The refrigeration connections are now complete.
Proceed to sections 4 and 5 to continue with other
service connection requirements before
completing section 6, the start-up procedure.
4. ELECTRICAL CONNECTIONS
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker.
Remove the plug from the mains socket before
any maintenance, repairs or cleaning is
undertaken.
* This icemaker should not be installed:
a) Where the power supply is not within the range of
220 - 240V.
b) Where the icemaker cannot be plugged directly
into its own power supply without using an
extension cord or sharing a receptacle.
92U2CM20B0303
3/8" OD
Liquid Line
Suction Line
Fig. 6
WARNING
* The main control box fuse is rated at 12A and should
only be replaced by a qualified service engineer.
* Usually an electrical permit and services of a licensed
electrician are required.
* If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured Green-and-Yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire which
is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Black.
The wire which is coloured Brown must be connected
to the terminal which is marked with the letter L or
coloured Red.
* Should the socket outlets in the installation site not
be suitable for the plug supplied with your product,
the plug must be removed (cut off if it is moulded on
plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power
supply cord, it must be disposed of. There should
be no attempt to reuse it. Inserting such a plug into
a socket elsewhere presents a serious risk of
electrical shock.
* The non-rewirable plug must never be used without a
fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's reference
number stamped on the plug.
Supply of replacement fuse covers can be obtained
from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS
1362.
3
ENGLISH
or