Samsung DV-1A Manual Del Usuario página 22

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Review Gas Requirements
section.
Remove the pipe thread
protective
cap.
Apply pipe joint compound
or about 1 1/2 wraps of Teflon tape over all threaded
connections.
[_
Pipe
must be resistant to the action of
joint compound
any liquefied
petroleum
gas.
Connect
the gas supply to your dryer.
An additional
fitting is required to connect
the 3/4" (1.9 cm) female thread end of a flexible connector
to
the 3/8" (1 cm) male threaded
end on the dryer.
Securely tighten the gas line fitting over threads.
Turn on the gas supply. Check all gas connections
for leaks using a soap solution.
If bubbles appear, tighten the connections
and recheck.
DO NOT use an open flame to check for gas leaks.
3-WIRE system connections
t.
Loosen or remove the center terminal
block screw.
2.
Connect
the neutral wire (white or center wire) of the power
cord to the center, silver-colored
terminal
screw of the
terminal
block. Tighten screw.
3.
Connect
the other wires to outer terminal
block screws.
Tighten screws.
4.
Tighten the strain relief screws.
5.
Insert the tab of the terminal
block cover into your dryer's
rear panel slot.
Secure the cover with a hold-down
screw.
1. External ground
connector
2. Neutral grounding
wire (green/yellow)
3. Center silver-colored
terminal
block screw
4. Neutral wire (white or center wire)
5.3/4"
(1.9 cm) UL-listed
strain relief
/_
If converting
from a 4-wire electrical
system to a 3-wire, the ground
strap must be
_AR.,N_ r econnected
to the terminal
block support to ground
the dryer frame to the neutral
conductor.
22
installing your _dryer

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dv433eSk-5a

Tabla de contenido