Palazzetti MULTIFIRE NICOLAS Manual De Instalación, Uso Y Mantenimiento página 40

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.5 FLUE GAS EXHAUST
The stove operates with negative pressure in the
gas discharge and corresponding joints must be
airtight.
The stove must be connected to its own
ensuring adequate atmospheric dispersion of the
combustion byproducts.
conditions and bear the CE mark.
have a nominal diameter of 15 cm or higher (based
on the length of the chimney).
rock wool) or made using double wall steel pipes,
except for the initial vertical section inside the
room.
An initial vertical section measuring a minimum of 50
cm
There should be at most three changes in direction
chimney connection, with the horizontal length of
Use always connector with inspection cap on all
connected to:
a chimney used by other heat generators
air exhaust systems (range hoods, vents, etc.....)
even if these are ducted.
Shut-off or draught valves must not be used.
Combustion byproducts must be discharged
through the roof.
40/144
INSTALLATION
cod. 004771980 - 09/2014 - Palazzetti - PN - Italy

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Multifire ariaMultifire airMultifire aire

Tabla de contenido