6 INSTALLATION
in compliance with EN 10683.
6.1 LEVELLING THE STOVE
The stove must be levelled by adjusting the feet
(where featured), then checked using a spirit level
(Fig. 6.1).
A B = Spirit level

6.2 SYSTEM CONNECTIONS

6.2.1 Electrical connection

The stove is connected to the electrical system
simply using the plug supplied.
The electrical connection (plug) must be easily
accessible when the stove is installed.
If the power cord is damaged it must be replaced
to prevent any kind of risk.
6.2.1.1 Eart
residual current circuit-breaker in accordance with
legislation in force (Fig. 6.2).
6.2.2 Connection to an external timer thermostat
The stove can be connected to an external timer
thermostat that switches the stove on or of
according to the set temperature.
When the set temperature is reached the
thermostat opens the circuit and consequently
switches off the stove.
The external thermostat is connected to the two
terminals on the board of the stove, which are
jumpered in the factory . Disconnect the jumper
and connect the two thermostat contacts.
the instructions shown in the paragraph on "Initial
needs to be switched on manually, while the timer
thermostat is in "call" status. This operation is also
required in the event of power failures or if the stove
is switched off manually.
To avoid overlapping the working time bands, it' s
recommend to disable (set to OFF) the stove' s timer
(see par. 10.1).
42/144
INSTALLATION
f
Fig. 6.1
Fig. 6.2
cod. 004771980 - 09/2014 - Palazzetti - PN - Italy