10.13 HYDRAULIC SYSTEM

Reservoir Capacity
Total System Capacity
To check the hydraulic fluid level on units that DO
NOT have the electronic Turf Protection System
(leak detector), locate the sight glass on the tower
portion of the reservoir. Visually inspect to see if
there is 1/2" (13mm) (at ambient temperature) of
fluid visible above the lower portion of the sight
glass. If not, unscrew the reservoir cap and fill to
proper level (See Fig 10.13).
18.0L
25.5L
JACOBSEN G-PLEX III Series: DN & DP
SAFETY AND OPERATORS MANUAL
Figure 10.13
1. Sight Glass
2. Reservoir Cap
3. Tower