Operating Instructions and Assembly Instructions
Airless Paint Sprayers
CLEAN UP FOr CHANGING PAINTS
Or TEMPOrAry STOrAGE FOr
MOrE THAN ONE NIGHT
WEAr ALL NECESSAry
SAFETy GEAr
NECESSAry TOOLS / MATErIALS:
• Pliers
• Rag
• Gloves
• Two (2) buckets
• At least one (1) gallon of cleaning
fluid
• cleaning brush
NOTE: DO NOT disconnect any hoses.
NOTE: Refer to coating manufacturer
for recommended cleaning fluid.
1. Turn prime/spray control to PRIME
position.
2. Start the engine.
High pressure
hose MaY still be
pressurized with prime/spray control
in the priMe position. with the gun
pointed away from your body or other
people, pull the gun trigger to relieve
any pressure in the hose.
3. Turn pressure to HIGH (completely
clockwise).
4. Lift suction assembly out of bucket,
allow pump to run until empty.
5. Immediately place both suction
assembly and bypass tube in a
bucket containing enough cleaning
fluid to cover suction bell by two
inches. Allow pump to prime and
begin circulating fluid.
6. While fluid is circulating, soak rag
in fluid and wipe exterior of suction
assembly and bypass tube. Remove
suction filter with pliers. Wipe
inside of suction filter housing with
rag removing excess paint buildup.
Clean both sides of suction filter
with rag and reinsert filter into
suction filter housing.
NOTE: DO NOT allow fluid to circulate
for more than 15 minutes.
Cleaning Pump
1
Turn Prime/Spray
Control to PRIME
Position
3
Turn Pressure to HIGH
(completely clockwise)
5
Suction Assembly and
Bypass Tube in Bucket
of cleaning fluid
13
13
2
Start Engine
4
Lift Suction Assembly above
Paint Level in Bucket
6
Wipe Exterior of Suction
Assembly and Bypass Tube
www.chpower.com