Installer Setting - Setting Address of Central Control
TIME (3 s)
Installer Setting - Checking Address of Central Control
1. With the FUNC. button pressed, press the RESET button.
2. Press the ON/OFF button toward the indoor unit 1 time, and the indoor unit will display the set
address in the display window.
• The address display time and method can differ by the indoor unit type.
3. Reset the remote controller to use the general operation mode.
°C/°F (5 s)
INSTALLATION INSTRUCTIONS
1. With the MODE button pressed, press the
RESET button.
2. By using the temperature setting button, set
the indoor unit address.
• Setting range : 00 ~ FF
3. After setting the address, press the ON/OFF
button toward the indoor unit 1 time.
4. The indoor unit will display the set address to
complete the address setting.
• The address display time and method can
differ by the indoor uint type.
5. Reset the remote controller to use the general
operation mode.
27