5. Move the '>' cursor to 'clock': Press q or p.
6. Press OK.
7. Move the '>' cursor to 'Set clock': Press q or p.
8. Apply 'Set Clock': Press OK.
The display shows (example):
Set Clock
Mo 15:30
YYYY-MM-DD
2015-03-23
9. Select the day of the week: Press q or p.
10. Move the '>' cursor to the next position: Press t or u.
11. To change the time: Press q or p.
12. To set the correct time of day, repeat the previous steps 10
and 11.
13. To set the correct date, repeat steps 10 and 11.
14. To confirm the entries: Press OK.
15. Press ESc (2x).
Summertime/wintertime
To set summertime/wintertime, proceed as follows.
1. Press q to show time + date.
2. Press ESc.
3. Select 'Set..' Press q or p.
4. Press OK.
5. Move the '>' cursor to 'clock': Press q or p.
6. Press OK.
7. Move the '>' cursor to 'S/W Time': Press q or p.
8. Press OK.
The display shows:
>On
Off
S/W Time
Off
9. Move the '>' cursor to 'On': Press q or p.
10. Confirm 'On': Press OK.
The display shows:
EU
11. Press u to select the applicable time zone.
12. Press OK.
The display shows (assuming you have set European time):
>On
Off
SW/Time:
On  EU
Europe/UK/US/Australia/Tasmania/New Zealand/Freely
adjustable: customized switchover dates and times.
4.11
commissioning checklist
#
check
1.
Are all connections airtight?
2.
Is the jumper setting correct?
3.
Is the direction of rotation of the fan
correct?
0000104046/150915/0 MultiDust Bank COMPACT
#
4.
5.
6.
5
5.1
The FilterControl panel contains the following controls and
indicator lights:
Fig. 5.1
controls
A
B
C
Indicator lights
D White light
E
F
11
D
E
F
Ref.
OK
section
4.9
4.6.1
Fig. 5.1
4.6.2
11. Option: additional strobe light to meet the IFA W3 certification requirements.
check
Is compressed air available?
Pressure setting 4-5 bar?
Is the parameter setting of the PLC
correct?
Is the rotary switch in position 1?

USE

WARNINg!
Fire hazard! Do not use the product for polishing
applications in combination with grinding, welding or
any other application that generate sparks.
Filtercontrol panel
Push button
START/STOP FAN
Push button
MANUAL CLEANING
- reset alarm
push shortly
- manual
push and hold for 5 seconds; the red
cleaning
light (E) starts blinking
- precoat timer
push and hold for 10 seconds; the red
reset
light (E) stops blinking
Rotary switch 0-1
Off
Power off
Red light
System OK
11
Green light
Fan off
POWER ON
ALARM
FAN RUNNING
Control panel
Ref.
section
4.7
4.10
5.1C
On
Power on
Cleaning cycle not
successful because:
- filter cartridges are
clogged; or
- no compressed air is
available
Fan on
START/STOP FAN
MANUAL CLEANING
0
1