Filter Cartridges; Electric Connection - PLYMOVENT MDB-2 COMPACT Manual De Instalación Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 60
Fig. 4.1
• Insert the 4 screw studs (A) in the bottom of the unit.
• Attach them to the platform or frame with the 4 locknuts
(B).
• Make sure that the unit is level.
>2 mm
Fig. 4.1
Mounting on platform or frame (image of frame indicative
only)
4.5

Filter cartridges

To install the filter cartridges, proceed as follows.
Fig. 4.2
• Loosen the star knob (F) and disassemble the cover plate
(E), the nut (D) and the metal washer (C).
• Put the filter cartridge (B) on the cartridge holder (A).
• Install the removed parts in reverse order.
A
B
Fig. 4.2
Installation of the filter cartridges
0000104046/150915/0 MultiDust Bank COMPACT
max. 2 mm
A (4x)
B (4x)
>2 mm
C
D
E
F
ATTENTION
Make sure that the front of the filter cartridge
aligns
with the filter housing, so that the lid closes
*)
well. If this is not the case, the filter cartridge is not
positioned correctly. This can cause leakage and less
efficient operation of the filter cartridge.
tolerance: max. 2 mm (0.1 in.)
*)
>2 mm
• Do the same procedure for the remaining filter
cartridge(s).
4.6

Electric connection

cAUTION!
The electric connection must be executed in
accordance with the local requirements. Ensure
compliance with the EMC regulatory arrangements.
To be sourced locally:
*) cable
cable
specifications
A
Mains cable
single phase + earth
1 mm² (3G1/
AWG18)
Mains cable
three-phases +
earth 4 mm² (4G4/
AWG10)
Fan cable
three-phases +
earth 4 mm² (4G4/
AWG10) (shielded
cable)
PTC cable
2-cored 0,75 mm²
(2xAWG18) (shielded
cable)
B
Connection
2-cored 0,75 mm²
cable
(2xAWG18) (shielded
cable)
C
Connection
8-cored (including
cable
earth wire) 0,75
mm² (8xAWG18),
PVC outer sheath
D
Connection
2-cored 0,75 mm²
cable
(2xAWG18)
*) Corresponds with the cable glands indicated in Fig. 4.3
4.6.1
FilterControl panel
The FilterControl panel must be installed at a clearly visible
and accessible position.
max. 2 mm
>2 mm
For
To:
connection
of:
FilterControl
the mains
panel
frequency
the mains
inverter or
other start/
stop device
fan motor
frequency
inverter or
other start/
stop device
fan motor
frequency
inverter or
other start/
stop device
PLC
frequency
inverter or
other start/
stop device
filter unit
FilterControl
panel
pressure
FilterControl
transmitter
panel
EN - 8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mdb-4 compactMdb-6 compact

Tabla de contenido