Daily Cleaning; Weekly Cleaning - EdilKamin PELLBOX SCF Instalación Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
SERVICING
Regular maintenance is essential for good insert operation
Before carrying out any maintenance, disconnect the device from the mains power supply.

DAILY CLEANING

Clean with a vacuum cleaner. The whole process takes a few minutes a day.
USING A VACUUM CLEANER, when the insert is cold:
- Vacuum-clean the door, the hearth and the space around the combustion chamber where the ash falls.
- Remove combustion chamber, clean it with the small metal box, and unblock any blocked holes on all sides.
Vacuum-clean the combustion chamber compartment and the edges which touch the housing, and replace the combustion chamber.
- If necessary clean the glass (when cold).
NEVER VACUUM-CLEAN HOT ASH, since it may damage the vacuum cleaner.

WEEKLY CLEANING

Pellbox SCF has two spy holes on the hearth "A" and two on the ceiling of the firebox "B" which allow easy effective
access for cleaning the smoke duct.
- essential smoke duct cleaning
"B"
"A"
- Empty the hopper and vacuum-clean the bottom if the insert is left unused. Do this in any case once a fortnight.
EVERY SEASON
(by the DEALER)
- After 2500 kg of pellets are consumed, the display shows the word "service", which means maintenance is needed.
- General internal and external cleaning
- Carefully clean heat exchange pipes
- Carefully clean and descale combustion chamber and corresponding compartment
- Clean fan and mechanically inspect play and fastenings
- Clean smoke duct (replace gasket on smoke outlet pipe)
- Clean smoke extractor fan compartment and flow sensor, and check thermocouple
- Clean, inspect and descale ignition heating element compartment and change the heating element itself if necessary
- Clean/check display-control panel
- Visually inspect electric cables, connections and power cord
- Clean pellet hopper and check screw feeder-gearmotor assembly play
- Change door seal
- Test screw feeder loading, ignition, operation for ten minutes and shutdown
If the insert is used frequently, it is advisable to clean the smoke duct every 3 months.
FAILURE TO CARRY OUT MAINTENANCE LEADS TO FORFEITURE OF THE GUARANTEE.
32

Publicidad

Tabla de contenido
loading

Tabla de contenido