UL Statements
Environmental Ratings tested to: Ambient 0 and 49 C, 85%
Humidity at 30 C.
UL294 Access Control Levels tested to:
Destructive Attack LV 1
Line Security LV 1
Endurance LV 4
Standby Power LV 1
The unit is intended to be installed within the Protected Area.
The unit is not intended for connection to outside wiring,
covered in Article 800 in NEC/NFPA 70.
The control unit must be powered by a Listed UL 294 Class 2
power limited power supply, or UL 294, UL294B Listed PSE/
PoE Injector rated 48V dc nominal, with range of 37 - 57 V
dc capable of providing 4 h of standby power. The minimum
conductor gauge permitted to connect between the PoE PSE
or power injector and the PD shall be 26 AWG.
Provided A/C adaptor not for use with UL 294 Listed Gateway.
ACP DC power input, RS485, PoE/Ethernet are Class 2.
Port
RS485 data
-7VDC to
terminal block
+12VDC
RS485 power
+12VDC to
terminal block
+24VDC
Barrel Plug
+24VDC
PoE
+48VDC
Compliance with IEEE 802.3 (af) specifications was not
verfied as part of UL 294 / UL 294 B.
The unit has been tested for compatibility with a UL 294
Listed, NDE-Series, Model NDE80 Schlage Engage Wireless
Lock.
The IP Mode of the ENGAGE Gateway was not evaulated by
UL to provide access control functions between the ACP and
locks.
Locations and wiring methods shall be in accordance with
the National Electrical Code, ANSI/NFPA 70 for U.S. and
Canadian Electrical Code for Canada.

FCC Statement

This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communication. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
Voltage
Current
+/-100uA
0.25A
0.25A
58mA
turning the equipment off and on, the user is encouraged to try
to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
FCC Caution: Any changes or modifications not expressly
approved by the party responsible for compliance could void
the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operation.
FCC Radiation Exposure Statement
To comply with FCC/IC RF exposure requirements for mobile
transmitting devices, this transmitter should only be used or
installed at locations where there is at least 20 cm separation
distance between the antenna and all persons.
Industry Canada Statement
Under Industry Canada regulations, this radio transmitter
may only operate using an antenna of a type and maximum
(or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users,
the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more
than that permitted for successful communication.
Industrie Canada Déclaration
Conformément à la réglementation d'Industrie Canada, le
présent émetteur radio peut fonctionner avec une antenne
d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les
risques de brouillage radioélectrique à l'intention des autres
utilisateurs, il faut choisir le type d'antenne et son gain de
sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.)
ne dépasse pas l'intensité nécessaire à l'établissement d'une
communication satisfaisante.
Industry Canada Radiation Exposure Statement
This Device complies with Industry Canada License-exempt
RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including
interference that may cause undesired operation of the
device.
Industrie Canada l'exposition aux radiations
Le présent appareil est conforme aux CNR d'Industrie
Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et
(2) l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le
fonctionnement.