Machine Assembly; Instructions For Attaching Autofeed Assembly; Pre-Operation Inspection - Rigid Auto-Clean K-30 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

before cleaning is through visual inspection with a camera.
Improper use of this drain cleaner can damage the drain
cleaner and the drain. This machine may not clear all
blockages.
Guide Hose
AUTOFEED
®
Figure 1 – Auto-Clean Drain Cleaner
Figure 2 – Machine Serial Number
The machine serial number is located on the back of the
housing. The last 4 digits indicates the month and year
of the manufacture. (04 = month, 10 = year).

Machine Assembly

WARNING
To reduce the risk of serious injury during use, fol-
low these procedures for proper assembly.
Instructions For Attaching AUTOFEED
Assembly
1. Put the tip of the cable into the guide hose (Figure 3)
and feed it through the hose to the AUTOFEED
assembly.
2. The bulb head auger will not fit through the AUTO -
FEED
®
assembly. Pull up on both the ADVANCE
and RETRIEVE levers and then feed the cable
through the AUTOFEED
ON/OFF/REV
Switch
GFCI
(If Equipped,
120V Units)
Foot Switch
Cable
Date
Code
®
. (Figure 4)
Auto-Clean™ Drain Cleaning Machine
Figure 3 – Feeding Cable into Guide Hose
Figure 4 – Feeding Cable Through AUTOFEED
Assembly
3. Release the ADVANCE and RETRIEVE levers.
4. Attach the guide hose to the machine by pushing
the hose over the nose of the drum cover. (Figure 5)
Figure 5 – Attaching Guide Hose to Machine

Pre-Operation Inspection

®
Before each use, inspect your drain cleaning ma-
chine and correct any problems to reduce the risk of
®
WARNING
5