Logic
Definition
Inversion of the
change
ot
motor's phase shift
OPEN IN OTHER
Open in other
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
Configuration of
safety input SAFE 2.
SAFE 2
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
Configuration of
AUX 0
AUX 0 output. 20-21
Configuration of
AUX 3 output.
AUX 3
26-27
Fixed code
FIXED CODE
Protection
Setting the
protection level
level
36 -
THALIA
INSTALLATION MANUAL
Cross out
Default
setting
used
0
0
1
0
0
1
0
1
0
2
72
3
4
5
6
7
8
9
10
6
74
11
12
13
14
0
1
0
2
61
3
4
4
5
62
6
0
1
6
2
3
4
5
6
0
7
8
9
10
0
0
1
0
1
0
2
3
4
Open: M1 starts in advance compared to M2 (opening phase shift). (See Fig.E)
Closure: M2 starts in advance compared to M1 (closing phase shift). (See Fig.E)
Pedestrian manoeuvre is performed by M1
Open: M2 starts in advance compared to M1 (opening phase shift). (See Fig.E)
Closure: M1 starts in advance compared to M2 (closing phase shift). (See Fig.E)
Pedestrian manoeuvre is performed by M2
Standard operating mode (See Fig.E).
Opens in other direction to standard operating mode (See Fig. E)
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2.
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
movement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
closing, the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
movement stops.
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
movement stops.
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as Ped.
Input configured as Timer.
Input configured as Timer Pedestrian.
Output configured as 2nd Radio Channel.
Output configured as SCA, gate open light.
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light
Output configured as Alarm
Output configured as Flashing light
Output configured as Latch
Output configured as Magnetic lock
Output configured as Maintenance
Output configured as Flashing Light and Maintenance.
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters
by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the
receiver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio
interference, if any.
Optional extras