5
ALARM MANAGEMENT
If a malfunction occurs, the following procedure is activated:
1) audible alarm (beep);
2) one of the following system LEDs come on:
3) if the problem concerns an error, the stove will switch off.
Pressing and holding the "cancel" button
WARNING CODE
E001
E002
E004
E101
E106
E108
E110
E111
A001
A002
A004
A005
----
----
----
* Only for the models equipped with safety microswitches on the door or on the hopper lid.
After having checked the type of message, the alarm can be reset by pressing the on/off button
moments.
If the error code is "
stove (Fig. 6.1)
22
DESCRIPTION
Faulty control panel
Remote control signal communication error
Communication error
Failed ignition error
Pellet probe malfunction
Pressure error or thermal safety
Safety error(*)
Temperature probe malfunction
Flue gas temperature probe malfunction
Low pellet level
Scheduled maintenance warning
Battery discharged
Failure of the Hall sensor
Clean stove
Failed ignition error
Fumes overtemperature
E108
", before resetting the alarm, manually reset the thermostat located on the rear of the
;
shows the error code on the display:
Control panel fault
Control panel fault
Connection cable between board and control panel
interrupted or detached.
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
Pellet probe disconnected or faulty
Flue gas exhaust system dirty
Seal gaskets worn
Problems with overheating in the pellet hopper
Door or hopper lid open (*)
Faulty air temperature probe
Pellets running out
The stove periodically requires maintenance to be
Battery discharged (mod. CR2032).
Hall sensor of smoke fan disconnected or faulty
Shut down during the ignition phase.
Burn pot dirty or clogged.
No pellets; Faulty ignition heater; Worn gaskets;
Incorrect burn pot position
Output system of the fumes dirty. The installation of
the stove is not correct
POSSIBLE CAUSES
LED
for a few