Wiring The Hood With An Inline Blower - Thermador PROFESSIONAL VCIN JP Serie Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Wiring the Hood with an
Inline Blower
1/ 8
12
"
(308 mm)
7/ 8
ø 9
"
(251 mm)
Figure 11: Wiring the Hood with an Inline Blower
English 14
12 "
(305 mm)
7/ 8
" (22 mm)
1/ 8
19
(486 mm)
3/ 4
1
(44 mm)
7/ 8
12
"
(327 mm)
3/ 8
14
"
(365 mm)
VTI1010D
Figure 10:
Inline Blower
VCIN
Both
and
installed with inline blowers. For complete installation
instructions see the instructions supplied with the blower
unit.
1. Remove junction box channel covering the wires (see
Figure 5 on page 11).
2. Remove circular knockouts (Figure 5 on page 11).
3. Install 1" (25.4 mm) conduit connectors.
4. Run black, white, and green wires (#12 AWG) in 1"
(25.4 mm) conduit from power supply to junction box.
5. Connect the power supply wires to the hood wires in
"
the following order: black to black, white to white, and
green wire to green ground screw on chassis. Use
spring type wire nuts supplied.
Lost or missing wire nuts should only be replaced
with spring type wire nuts, rated for a minimum of
"
two (2 #18 gauge wires and maximum of four (4)
#14 gauge wires, UL & CSA rated to 600V and
302°F (150°C).
6. Connect the "pigtail" to the connector inside the
junction box.
7. Run five (5) wires (#14 AWG) in 1" (25.4 mm) conduit
from the inline blower to the second conduit connector.
8. Connect the inline blower to the pigtail wires as per
Figure 11. Connect the inline blower green (ground)
wire to the ground screw in the junction box.
9. Close the junction box cover.
VCIB
custom insert models can be

Publicidad