DOUBLE DUCT PIPING (-5.11A-)..
pipe can be used to carry hot air to the other rooms of the
house.
5.7
SINGLE DUCT PIPING (-5.11B-).
pipe up to the opening of the appropriate distribution
channels.
The air distribution pipes must have an inside cross section
and insulated with a 30 mm thick layer of glass wool to
prevent noise and the loss of heat.
rooms, it is essential to help the recycling of the ambient
air to keep the temperature the same in each room. For this
purpose, install transit grilles on the doors or keep them ajar
5.8

CONNECTION TO THE FLUE

and curves in aluminate steel or stainless steel. It can
be connected in two different ways:
A)
B) Connection using the telescopic pipe kit
(optional).
This is the way to do it if you are installing
space of 2 ÷ 12 cm between the base of the connection
and the upper part of the device.
in the pre-hood ring must be sealed accurately (-5.14a-
In fact, if the sealing is not perfect, air could get through
door will turn black. Another consequence would be heat
in wood less than 16 cm away from the top edge of the
device, such combustible material must be protected from
heat with an insulating panel made of cement chip or any
other suitable material (-5.14c-).
5.9
RECESSING IN FIREPLACES
the bottom of the collar (at the top). Then move the device
2/3 mm thick metal sheet guides under it, which must be
If
A
29
- 5.11A -
- 5.11B -
B
C
2-12 cm
- 5.14 -
- 5.15 -