TROUBLESHOOTING GUIDE

Condition
Unit will not turn on - No GREEN or
RED LED illuminated on control cap
Unit runs briefly, won't develop
pressure, then turns off
Unit won't start with water demand
Unit continuously cycles ON/OFF
(Rapid Cycle)
Unit won't turn on
Unit runs or cycles continuously
NOTE: The motor in this unit contains thermal protection that responds to motor current and heat from the motor winding and ambient
temperature. When the combination of current and heat exceeds a pre-determined point, the protector opens and interrupts the circuit.
When the winding temperature returns to a more normal level, the protector will automatically reset.
16
Indicator Lights
None
Circuit breaker tripped or turned off
None
Circuit breaker tripped or turned off
Flashing Green (10s)
Insufficient water
then flashing RED
Flashing Green (10s)
Unit insufficiently primed
then flashing RED
Flashing Green (10s)
Dry running
then flashing RED
Solid Green
Inlet water pressure above 40 psi
Flashing Green
Improper charge pressure in tank
Flashing Green
Check valve between tank and unit
Solid RED
Unit is turned OFF
Flashing RED
Overvoltage (input voltage higher than +10%)
Flashing RED
Undervoltage (input voltage lower than -10%)
Flashing RED
Overheating due to excessive water temperature Supply cold water to the pump
Flashing RED
Pump is in alarm condition
Flashing Green
Leak/usage above 1/2 gpm in system plumbing
Flashing Green
Internal non-return valve is blocked/damaged
Flashing Green
Internal flow piston is stuck open
Possible Cause
Turn on the circuit breaker
Consult a licensed electrician to
properly wire outlet
Check water supply and valving
Refer to owner's manual section on proper
priming technique
Check water supply and valving
Install a pressure reducing valve on inlet to
reduce inlet pressure
Set the pressure in pressure tank to 2 psi
lower than cut-in pressure
Place check valve after pressure tank
Press the power button on the user interface
Check the supply voltage and correct if possible
Check the supply voltage and correct if possible
Reset pump by pressing power button
Repair the leaking plumbing
Place a new non-return valve before unit in
INLET plumbing
Clean the flow piston (see page 14)
Corrective Action