Pedestal
Installing this element raises the height of the charging station from the ground by 200 mm.

2.3. Compliance with regulations

CE marking
CE marking is mandatory for the sale of any product within the European Union, without prejudice to standards or
laws. INGEREV charging stations have the CE marking because of their compliance with the following directives:
Low Voltage Directive 2006/95/EC.
Electromagnetic Compatibility Directive 2004/108/EC.
To comply with each directive, compliance with the parts applicable to our units of the appropriate harmonised
standards is sufficient.
Low Voltage Directive
INGEREV units comply with this directive by means of compliance with the applicable parts of harmonised
standard EN 61851 Electric vehicle conductive charging system.
Electromagnetic Compatibility Directive
INGEREV units comply with this directive by means of compliance with the applicable parts of harmonised
standards:
EN 61000-6-2 Electromagnetic Compatibility. Part 6-1: Generic standards - Immunity for residential,
commercial and light-industrial environments.
EN 61000-6-3 Electromagnetic Compatibility. Part 6-3: Generic standards - Emission for residential,
commercial and light-industrial environments.
Compliance with these standards calls for compliance with limits and procedures in other standards of the same
series.

2.4. EMC requirements

These charging stations have the necessary filtering elements to comply with EMC requirements for domestic
applications in order to prevent disturbances in other equipment outside the installation.