Verify that the unit's label values are compatible with main power supply.
! ATTENTION!
Generally it is preferred to turn off the unit when the circulation pump is turned off, for this reason it is recommended to
follow the electrical installation of the figure
To avoid damages to the circuit board do not install the power supply of the pump directly in parallel with filtration pump
power supply but use a relay. The unit is switched on when the display is lit.
PERIODIC MAINTENANCE
Calibration of the unit
The measuring probe is regarded as a replacing worn part in fact it undergoes a natural aging
depending on its use, therefore it does not fall under the warranty.
ELECTRODE CLEANING
Dip the electrode into an acid solution like vinegar (max 2% acid 98% water). Wait five minutes and rinse it with water. It
is advisable do not to leave the electrode dry; if it is stored for long time it must be covered with the plastic cap appositely
filled with water to keep it with its tip wet
FRONTAL PANEL DESCRIPTION
GENERAL FUNCTIONS OF THE CONTROLLER :
- 4 LANGUAGES MENU: ITALIAN, ENGLISH, FRENCH, SPANISH
- 3 POSSIBLE TYPES OF FUNCTIONING: MANUAL, ON/OFF, PROPORTIONAL
- ALARM TIME
- START UP DELAY
- STAND_BY : TEMPORARY DEACTIVATION OF THE ELECTRICAL SOCKET
- REAL TIME ACTIVATION % VISUALIZATION
- WATER FLOW CONTROL (upon request)
- LEVEL CONTROL (upon request )
- OVER RANGE AND UNDER RANGE OF THE MEASURE
type Rx:
FUNCTIONING: ON/OFF
SETPOINT: 730mV
ACTIVITY DIRECTION : Oxid
WARNING:
MENU "RESTORE DEFAULT SETTINGS"
DEFAULT SETTINGS
DO NOT ENTRY THE RESTORE MENU!!!!
PUSH ESC BUTTON OR + OR – BUTTONS TO EXIT THIS MENU
Cod. 00.008.574 Rev 1.0
1 time every 3 months or in case of measure drift
1.Display LCD 8 x 2 backlight
2.Green Led: ▪ fix = controller ON
▪ blinking = controller IN ALARM
3.Red Led: continuously lit on indicates the electrical
socket's activation
4.CAL button : ▪ allows to enter in programming
▪ saves the changes
5/6. – and + buttons : ▪ allows to navigate through the
7. ESC/SBY button: ▪ puts the controller in stand_by
Delay On : 0sec
FLOW RATE: 100% (SOCKET ACTIVATION %)
ALARM TIME: 0unit (disabilitato)
START UP DELAY: 3 sec
menu
▪ Modify the parameters values
mode
▪ allows to exit the menu
RESTRICTED