4.2.5.1
TILT mode configuration.
Pressing the CONFIG [14]
key will access to the first page of
the configuration menu.
To change a given parameter turn the
rotary selector [9] until the field is activated (this
will appear shadowed) and then press. The value
of the parameter will be activated and may be
changed by turning the rotary selector. When the
value you want appears, press the rotary selector
[9] to validate it.
a) BAND
It permits to select between the FORWARD mode (5 to 863 MHz) and the
REVERSE mode (5 to 100 MHz). When selecting one of these modes, the
user can define the associated frequency.
b) PILOT 1
It defines a frequency belonging to the forward or reverse band where the
first measurement of level will be done. This parameter, and the rest of
pilots, is defined digit by digit, by pressing repeatedly and turning the rotary
selector.
c) PILOT 2
It defines the second pilot frequency belonging to the forward or reverse
band.
d) PILOT 3
It defines the third pilot frequency belonging to the forward or reverse band.
e) PILOT 4
It defines the fourth pilot frequency belonging to the forward or reverse
band.
To leave the configuration menu of the TILT mode, just press the key of the
operating mode you wish to access.
Page 36
Figure 42.- TILT configuration.
(REVERSE band)
USER'S MANUAL.
PROMAX-8
Figure 41.- TILT configuration.
(FORWARD band)
IMPORTANT
SE
09/2013