USE AND MAINTENANCE
11. .Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
4.1 
D.H.W. PRODUCTION 
The.preparation.of.hot.water.is.guaranteed.
by.the.glass.storage.tank.unit.with.magne-
sium.anode.for.the.protection.of.the.boiler.
unit. and. inspection. flange. for. its. control.
and.cleaning..
12. .Visualizzazione.codice.errore
The  magnesium  anode  must  be  checked 
.......ultima.anomalia
annually  and  substituted  when  it  is  worn, 
pain the forfeiture of the guarantee of the 
storage tank. If the boiler does not produ-
ce  hot  water,  make  sure  that  the  air  has 
been released by pressing on the manual 
vents  after  having  switched  off  the  main 
switch. 
13...Visualizzazione.codice.errore
4.2 
GAS VALVE (fig. 18)
.......penultima.anomalia
The.boilers.are.equipped.standard.with.the.
SIT.845.SIMGA.gas.valve.(fig..18)..
The.gas.valve.is.set.at.two.pressure.values:.
maximum.and.minimum..
According. to. the. type. of. gas. burnt,. these.
correspond.to.the.values.given.in.Table 4..
The. gas. pressures. at. the. maximum.
14...Visualizzazione.numero.totale
and. minimum. values,. are. factory. set..
.......delle.anomalie
Consequently.they.must.not.be.altered..
Only. when. you. switch. the. appliance. from.
one.type.of.gas.supply.(methane).to.another.
(butane.or.propane),.it.is.permitted.to.alter.
the.operating.pressure. 
.
4.3 
GAS CONVERSION (fig. 19) 
15. .Contatore.accessi.parametri
This  operation  must  be  performed  by 
.......installatore.(es..140.accessi)
authorised  personnel  using  original  Sime 
components.
To.convert.from.natural.gas.to.LPG.or.vice.
versa,. perform. the. following. operations.
(fig..19):
–. Close.the.gas.cock.
–. Disassemble.the.burner.manifold.(3).
–. Replace. the. main. nozzles. (6). supplied.
16.  Contatore.accessi.parametri
in.a.kit,.inserting.the.copper.washer.(4)..
.......OEM.(es..48.accessi)
Use.a.ø.7.spanner.to.perform.this.opera-
tion.
–. Configure. the. new. fuel. as. indicated. in.
point.4.3.1
–. For. calibrating. the. maximum. and. mini-
mum. gas. pressure. values,. see. point.
4.3.2.
.–.After. have. ultimated. the. conversion. of.
the. boiler,. please. stick. onto. the. casing.
panel. the. plate. showing. the. relevant.
feeding.gas.which.is.included.into.the.kit.
NOTE:  When  reassembling  compo-
nents  which  you  have  removed,  replace 
gas  seals;  test  all  gas  connections  after 
assembly  using  soapy  water  or  a  product 
made  specifically  for  the  purpose,  being 
sure not to use open flame. 
5
4.3.1 
New fuel configuration
For. access. to. the. installer's. parameters,.
press.simultaneously.keys.
TABLE 4
Model.
.
25/55 OF ErP. 11,0.
(*).. Max..burner.pressure.is.guaranteed.only.when.the.supply.pressure.exceeds.the.max..burner.pressure.by.at.least.3.mbar.
5
5
5.seconds.(3.fig..14)..
The. parameters. will. scroll. up. and. down.
with.the.keys.
The.display.pane.will.show.the.values.of.the.
1
parameter.PAR.1..
If,. for. example,. the. boiler. in. question. is. a.
25/55  OF  ErP. fuelled. by. methane,. the. fol-
lowing.setting.SET.9.will.appear:.
2
5
3
3
.and .
. for.
1
1
6
5
4
1
3
Burner.max.pressure.mbar.
Modulator.current.mA.
G20.(*). G30.
G31.
G20.(*). G30.
27,7.
35,7.
130.
165.
3
3
.and.
..
1
2
4
4
KEY
1. Modulator
2. EV1-EV2.coils
2
3. Pressure.inlet.upstream
4. Pressure.inlet.downstream
5. VENT.pressure.test.point
Burner.min.pressure.mbar.
Modulator.current.mA
G31.
G20.(*).
G30.
G31.
G20.(*). .G30.
165.
1,8.
4,7.
4,7.
KEY
. 1. Swivel.connection.1/2"
. 2. Locknut.1/2"
. 3. Burner.manifold
. 4. Washer.ø.6.1
. 5. Burners
. 6. Nozzle.M6
. 7. Screw
WARNING:  To  ensure  a  perfect 
seal,  always  use  the  washer  (4) 
supplied  in  the  kit  when  replacing 
nozzles,  even  in  burner  units  for 
which it is not specified.
5
To.change.the.fuel.to.LPG,.it.is.necessary.to.
set.SET.11,.by.pressing.the.key.
1
2
The. standard. display. will. automatically.
return.after.10.seconds.
The.table.below.shows.the.SET.settings.to.
enter.when.the.type.of.gas.fuel.is.changed.
ES
PT
ENG
G31
0.
0.
0
Fig..18
Fig..19
3
.
4
83