TECHNICAL DATA
Outdoor unit
Indoor Unit
TOL
TBivalent
Heating
A Condition
(Average climate)
(-7°C)
B Condition
(2°C)
C Condition
(7°C)
D Condition
(12°C)
Pto (Thermostat off)(Cooling/Heating)
Psb (Standby mode cooling)
Pcycc
Cooling
EERcyc
Cdc (Degradation cooling)
Pck (Crankcase heater mode)
Poff (Off mode)
Psb (Standby mode heating)
Pcych
Heating
COPcyc
Cdh (Degradation heating)
Table 14.1 Additional datasheet.
* We have different sound level datas according to different air flow volume or
frequencies, not according to the working temp.
NOTE:
i
As part of its policy for ongoing improvements of its
products, Vaillant reserves the right to modify these
specifications without prior notice.
- 24 -
Tol (temperature operating limit) °C
Pdh (declared heating cap)
COPd (declared COP)
Tbiv (bivalent temperature)
Pdh (declared heating cap)
COPd (declared COP)
Pdh (declared heating cap)
COPd (declared COP)
Pdh (declared heating cap)
COPd (declared COP)
Pdh (declared heating cap)
COPd (declared COP)
Pdh (declared heating cap)
COPd (declared COP)
VAI 3-025 WNO
VAI 3-025 WNI
-10
kW
2,4
2,6
°C
-7
kW
2,4
2,3
kW
2,4
2,3
kW
1,5
4,1
kW
0,9
4,9
kW
0,9
6,4
kW
0.035 / 0.012
0,001
kW
kW
NA *
NA *
0,25
kW
NA *
kW
NA *
kW
0,001
kW
NA *
NA *
0,25
VAI 3-035 WNO
VAI 3-050 WNO
VAI 3-035 WNI
VAI 3-050 WNI
-10
3
2,4
-7
3,1
2,4
3,1
2,4
1,9
3,7
1,2
5,2
0,9
5,9
0.039 / 0.01
0.05 / 0.013
0,001
0,0012
NA *
NA *
NA *
NA *
0,25
NA *
NA *
NA *
NA *
0,001
0,0012
NA *
NA *
NA *
NA *
0,25
VAI3-WN-I_EN - 07/14 - Vaillant
-10
4,3
2,4
-7
4,72
2,6
4,72
2,6
2,87
3,8
1,85
4,8
0,82
5,5
0,25
0,25