Setting The Alarm Threshold; Memory (C.A 6415 Only); Zero Reset Of Memory; Recording A Measurement - Chauvin Arnoux C.A 6410 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

According to the type of alarm selected, crossing of the alarm threshold will be
indicated by the appearance of
or
and a continuous beep at high or low fre-
quency.
AL
Press the AL button again to exit the alarm function (the
symbol disappears).
If the instrument is switched OFF, without the alarm mode being exited, this configu-
ration will be saved. The instrument will thus automatically switch the alarm function
ON again when the instrument is next switched ON.

Setting the alarm threshold

To programme the alarm threshold for resistance measurement it is necessary to first
press the ON + AL sequence.
AL
The
symbol is displayed and the last digit of the threshold value flashes, as a
reminder that you are in threshold reset mode. This value is changed by pressing the
Ω Ω Ω Ω Ω button (increase) or A button (decrease). This new threshold value will be kept until
it is again changed, even after the clamp has been switched OFF.
The high alarm threshold can be between 1 and 199 Ω. It is programmed in at the
factory before delivery of the clamp.
OFF (instrument switched off) exits alarm threshold programming mode.
MEMORY (
)
C.A 6415 exclusively

Zero reset of memory

Press the ON + MEM sequence for 3 seconds to display
, this starts the clear
memoory procedure. At the 5th beep, the memory is cleared. Return to resistance
measurement is then automatic.

Recording a measurement

The recording of a measurement is only possible if the memory is switched on with the
ON + A sequence (MEM symbol displayed).
Press MEM to record the displayed value. The number of values in memory goes up
by 1 and a long beep confirms the recording.
If the
symbol or the
symbol is continuously displayed, recording is impossible
because the clamp is not correctly closed or the battery is too low.
When the 99th value is recorded, the MEM symbol flashes to tell the user that the
memory is full. It is then no longer possible to record new values. If MEM is pressed
again there is no effect other than that a beep is emitted to indicate that recording is
prohibited. The memory should be reset to zero (after being re-read if necessary).