Energy gateway
EN
Scanning with output "S0" and RFTM-1
0 0 0 0 0 , 0 0
Impulse output
• S0 - contact, open collector, reed magnetic contact
- Impulse output meters marked "S0" connected to the GND and DATA1 terminals on the RFTM-1 sensor.
- When polarization is indicated on the meter, the terminals S0 + and S0- must be distinguished when
connected to the "S0" impulse output.
Notice
- RFTM-1 / RFPM-2M / sensors (LS, MS, WS) do not affect the consumption meter and do not affect the measurement of the measured quantity.
- Electricity meters, water meters and gas meters are the property of energy suppliers. Without their knowledge and permission, they are not allowed to interfere with internal connections (seals, supply
lines, etc.).
Installation of RFPM-2M
Connect the RFPM-2M to the power supply (can be powered from the monitored phase).
Use an Ethernet cable to connect it to your PC / Router. By default, static IP address 192.168.1.2 is set on RFPM-2M.
If you do not have the same IP range on the router, you need to set the same IP address range in your PC (Control Panel \
Network and Internet \ Network Connections \ Local Area Connection \ Properties \ Version 4 Protocol \ Use the following IP
address \ 192.168.1.10 - to make RFPM-2M available for confi guration.
After this, open a web browser (supported browsers: Chrome, Firefox, Opera, Safari - other browsers may not work properly).
Enter the IP address 192.168.1.2.
The RFPM-2M Web Environment opens, where you can confi gure your device.
RFPM-2 will require login through your username and password, which are set by default:
Name: admin
Password: admin
To successfully set the time from the NTP server, it is necessary to restart RFPM-2 after setting up its network.
In case the RFPM-2M is not connected to the Internet, the time can be updated using the "refresh" button on the web.
RFPM-2M will automatically notify you of this update by a red alarm in the upper right time window.
Note: Press and hold the RFPM-2 button for 10 seconds on the front panel of the instrument (RESET). The IP address and login
information will return to the factory settings.
Once logged in, you'll see an interface for managing and displaying measured data in your browser.
Graphical display
of measured states
Display of currently
measured states
Setting RFPM-2M
Detailed view of
interactive graph
Interactive graph
* Only update the fi rmware using a LAN connection. WiFi recording may not work correctly.
Made in Czech Republic
RF
RFTM-1
RFPM-2M
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech republic | e-mail: elko@elkoep.com
Scanning with output "S0"
0 0 0 0 0 , 0 0
Support: +420 778 427 366
EN
www.elkoep.com
RFPM-2M
Impulse output
Time and date settings
List of connected
Signal strength
This tab is primarily used to update the
fi rmware.
The current fi rmware is available at https://
www.elkoep.com/energy-gateway---
rfpm-2m
Download the fi rmware by selecting a fi le
on your computer and upload it to RFPM-
2*. After the new fi rmware is loaded, the
power can be retrieved for several minutes.
02-5/2018 Rev.1
S0+
S0 -
inputs
Version FW