Descargar Imprimir esta página

Fronius 3.0-3-S Manual De Instrucciones página 56

Ocultar thumbs Ver también para 3.0-3-S:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
Australia - Conduits
Seal cable protec-
Ensure that the cable protection hoses are tightly sealed.
tion hoses tightly
Seal Conduits
1
1
56
rigid or flexible
Outside
DC=
Conduit
AC~
Air circulation
Condensation
Outside
2
DC=
Conduit
AC~
4
Permanently elastic sealant
HINWEIS!
Condensation within the conduits can
Inside
damage the inverter or components of
the photovoltaic systems.
To avoid undesirable air circulation and
condensation in the conduits,
► seal all conduits being used with a per-
manently elastic sealant,
► seal every incoming and outgoing con-
duit,
► seal both conduit ends.
Conduit
Conduit
Inside
1
3
Conduit
Seal all used conduits!
Seal every incoming and every outgoing conduit!
Seal both conduit ends!
Conduit fitting
1
1
Permanently elastic
sealant
Inverter housing

Publicidad

loading