Safety Information; Risk Of Electric Shock - Pinnacle Protemp PT-45-KFA Manual De Usario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
The products described in this manual are kerosene
direct-fired, forced air heaters. Kerosene forced air
heaters are primarily intended for use for temporary
heating of buildings under construction, alteration or
repair. Direct-fired means that all of the combustion
products of the heater enter the heated space. This
appliance is rated at 98% combustion efficiency, but
does produce small amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
DANGER
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation in
accordance with the instructions in this manual can
result in death. People with breathing problems
should consult a physician before using this heater.
Early signs of carbon monoxide poisoning resemble
the flu. Symptoms of improper ventilation/carbon
monoxide poisoning are:
Headache • Dizziness • Nausea
Throat
Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater serviced
and check for proper ventilation. Some people are
more affected by carbon monoxide than others. These
include: pregnant women, those with heart or lung
problems, anemia or those under the influence of
alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED
ONLY FOR: The temporary heating of adequately
ventilated buildings or structures under
construction, alteration or repair. Provide at least a
three square foot (2,800 sq cm) opening of outside
air for every 100,000 Btu/Hr (29 kW) heater
rating. Refer to "Ventilation" on page 6 for further
instructions.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
®
SAFETY INFORMATION (CONT.)
RISK OF INDOOR
AIR POLLUTION!
CARBON MONOXIDE
POISONING MAY
LEAD TO DEATH!
Dry Mouth Sore
WHILE CONNECTED TO A POWER SOURCE
WARNING
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heater's fuel tank while the heater is
operating or still hot. This heater is EXTREMELY HOT
while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
WARNING
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
45-175T-KFA
Top
4 ft. (125 cm)
Sides
4 ft. (125 cm)
Front
8 ft. (250 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it is
plugged in, it can start at anytime in accordance with
the thermostat setting.
WARNING
TOUCH. KEEP CHILDREN, ANIMALS, CLOTH-
ING AND COMBUSTIBLES AWAY FROM HEAT-
ER.
3
Kerosene Forced Air Heater User's Manual
RISK OF ELECTRIC
SHOCK!
RISK OF BURNS,
FIRE AND
EXPLOSION!
215T-KFA
4 ft. (125 cm)
4 ft. (125 cm)
10 ft. (305 cm)
CAUTION! HOT
WHILE IN OP-
ERATION. DO NOT

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pt-80t-kfaPt-140t-kfaPt-175t-kfaPt-215t-kfa

Tabla de contenido