Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved fuel
until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a three
prong (grounded) extension cord that is at least 6
feet long and is a minimum of 14 AWG rating.
Model 45-KFA:
1. Complete steps 1-3 above.
2. Move power switch to "On" position. The power
indicator light will illuminate and the heater will
ignite.
Stopping / Restarting Heater:
- To stop the heater, move the power switch to the "Off"
position and unplug the power cord.
- To restart the heater; wait 10 seconds and follow ignition
steps.
TIP: If the heater does not ignite; move switch
to "Off" position, check steps 1-3 above and
then move switch to "On" position.
Models 80T-KFA - 215T-KFA:
1. Complete "starting heater ignition" steps 1-3 above.
2. Turn thermostat control knob to desired
temperature setting. The thermostat set range is
from 40 ºF to 110 ºF.
3. Move power switch to "On" position. The power
indicator light and room temperature display will
illuminate and heater will ignite.
NOTE: 45-80T-KFA models do not have a room
temperature display feature.
The room temperature display will indicate the
following:
- When the temperature is less than 0 ºF the
display says "LO".
- When the temperature is more that 99 ºF the
display says "HI".
- Between 0 °F and 99 °F the display shows actual
temperature.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
®
OPERATION (CONT.)
Stopping / Restarting Heater:
- To stop the heater, move the power switch to the "Off"
position and unplug the power cord.
- To restart the heater; wait 10 seconds and follow ignition
steps.
TIP: If the heater does not ignite, the thermostat
may be set too low. Turn the control knob to
a higher setting until the heater ignites. If the
heater does not ignite; move switch to "Off" position,
check steps 1-3 above and then move switch to "On"
position.
Long Term Storage:
Models 45-KFA - 80T-KFA:
1. Use an approved siphon to drain fuel through the fuel
cap opening.
Models 140T-KFA - 215T-KFA:
1. Drain fuel through the drain bolt in the bottom of
the fuel tank.
2. To remove the drain bolt, unscrew
counterclockwise. A 6 mm hex key (not provided) is
required to unscrew the drain bolt.
3. Using a small amount of kerosene, rinse and swirl
the kerosene inside of the fuel tank, empty the tank
fully.
4. To replace the drain bolt; push the drain head fully
into the drain hole and screw clockwise.
IMPORTANT: Never store leftover kerosene between
seasons, using old fuel can damage heater.
7
Kerosene Forced Air Heater User's Manual

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pt-80t-kfaPt-140t-kfaPt-175t-kfaPt-215t-kfa

Tabla de contenido