Product information/unwrapping
Aquarea Delta is a stainless steel indirect water heater.
The product is designed for heating domestic hot water
from an external heat source such as heat pump, solar
panel, gas boiler, biomass etc. Technical data, see table
below.
Unwrap the product carefully to avoid cosmetic damage.
Install the product on a flat, even surface designed to carry
the full weight of the product when filled with water. Adjust
the factory fitted adjustable feet as needed. The product
must be installed in an upright, level position. All piping and
electrical work must be performed by an authorized installer.
Before filling unit with water it is recommended to fit the
electric power cable, see 'Electrical installation' on next page.
Important:
Fill unit with water before turning power on.
Failure to comply will terminate guarantee.
On tilted floors the appliance must be installed upright and
level by adjusting the built-in feet. Units 250 I. and larger
must be securely fastened to the wall.
This appliance is intended to be permanently connected to
the main water supply.
All units are CE approved. Only safety valve approved to NBI
06870/387 is allowed for use with this product. All electrical
equipment is approved to LVD 2006/95EC (directive for low
voltage systems) and EMC 2004/108 EC (electromagnetic
compatibility).
Pipe fitting, see next page.
Guarantee, see page 4.
Electrical installation
All electrical installation and service must be performed by
authorized electrician. Thermostat is connected as shown.
Ground wire connects directly onto heating element.
The power supply cable is led into the electric central from
below. The cable can be fitted in the desired cable slot in
the unit base by turning the water heater on its back before
installation/filling.
DO NOT turn power on before unit is filled with water. Failure
to comply will terminate guarantee.
When heating the unit with an external heat source (gas boil-
er/heat pump/solar panels) the system must be secured with
a suitable thermostat to ensure the water heater thermal cut
off does not operate.
Note: The power cable must be fitted with an appropriate
strain relief at the point where it is fed into the electric cen
tral.
The Delta series is approved to IP 21.
Disconnecting the appliance from the main power grid must
be done with electric fuse or an appropriate switch.
Replacing the thermostat/element:
Turn off power supply and remove electric central cover.
Turn off water supply and drain unit. Unscrew wires on ther
mostat and element. If only the thermostat is being replaced
the wire on the element can be left on. The thermostat is
removed by pulling it straight out from its sockets on the ele
ment. The element can then be removed/replaced by using
an element tool, see 'Spare parts'. Ensure the o-ring seal on
the element is in place and undamaged before fitting the el
ement. Fill unit completely with water and make sure the ele
ment is not leaking. Fit wire to element. Install thermostat by
pressing firmly. Fit the electric wires to thermostat. Tighten
all wire connections thoroughly. Re-tighten after 3 months.
The electric central cover must be re-fitted and the unit must
be filled with water before power is turned on.
2
Subject to changes without notice
,,
�J
;����;!!!!!!!! !!::: = ====::=:=!!!!!!! !!= := = ==
sensor pocket
�
\
=
�
�
•
Thermostat Element
Ground wire
is connected
to the heating
element
Main power cable is
supplied by installer in
accordance with local
resiulations.
Minimum cable type is
HOS VV-F. Aquarea
recommends HOS V2V2
g(E
or similar.
Pipe fitting and connections
Pipe fitting:
The piping must be fitted in accordance with the current
regulations in the area where the product is installed. All pipe
fitting must be performed by an authorized installer.
Pipe connections:
Cw inlet: 3/4" BSP female
Hw outlet: 3/4" BSP female
Coil flow/ret: 3/4" BSP female
Connection heights and dimensions for all models, see next
page.
The product must be installed in a room fitted with a gully.If
this is not possible an overflow pipe (min. 018 mm internal)
must be fitted to the P& T/safety valve. The pipe must be
installed uninterruptable and safe from frost, sloping to a
dimensioned gully/drain.
Filling the unit
The unit MUST be filled with water before electric power
supply is turned on. Open main water supply. Drain air from
vessel through nearby hot water faucet until water flows
evenly. Close faucet.
Coil is filled when installing external heat source. Follow
instructions supplied with external heat source or contact
approved installer.
Draining
Turn off power supply. Turn off water supply. Drain unit by
disconnecting cold water inlet pipe. Open a nearby hot water
faucet to release vaccuum.
Draining coil: See instructions supplied with external heat
source. Disconnect return pipe to empty coil. .
Annual check-up
Perform first time after approx. 3 months in service, then
annually.
Check all pipe fittings for leaks. The function of the safety
valve must be tested by opening the valve and observing
that water flows freely. Close the valve after testing.
Check electrical connections for any damage. The internal
electric central is inspected by turning off the power supply,
then removing the el. box cover. Ensure that all internal
Temp.
wiring and components are intact and working. Tighten wire
sensor
connection points. Fit the el. box cover before turning power
supply back on. If needed contact authorized personnel.
Spare parts
Description
Product
Heating element RG 5/4" single tube with sensor pocket
Thermostat
TSR 00027 thermostat with sensor
KN 5/4" - f o r removing/f i tting the element
Element tool
El. box cover
Delta
Sensor
Temperature sensor
Technical Data Sheet
Water heater Efficienc
TRADEMARK
A uarea
IP21
A uarea
HW outlet
circ.
HW
Coil
inlet
CW inlet
Temperature sensor is supplied
with unit. Fit as shown.
Prod. No.
3-way valve installation: See heat
pump installation manual.
7123 4
80 314
3-way valve is not included. Must
801 5195
be purchased separately.
75 086
81809
Ratin ErP
PAW-TD 20 ClES - 1 SkW lx230V
A
PAW-TD 30 ClES - 1 SkW lx230V
A
Subject to changes without notice
Heat loss - W
stora evol.
42
194
46
284
3