Dyna-Glo DGA550SSN Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS
Connecting the Grill to the Natural Gas Supply
• The quick disconnect coupling (A1) and supply gas line must be installed by a qualified service
agency. The supply connection must be made in accordance with local codes or, in the absence
of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, in the USA, or the
Natural Gas and Propane Installation Code, CSA B149.1, in Canada.
• A properly sized manual shutoff valve must be installed between the grill and the gas supply piping.
• The grill and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 0.5 PSI (3.5 kPa).
• The grill must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 0.5 PSI (3.5 kPa).
• Always connect the flexible gas supply hose to the gas supply before opening the manual shutoff
valve.
To Connect:
1. Ensure that the manual gas shutoff valve is closed.
2. Remove the protective rubber caps from the plug and
sleeve ends of the quick disconnect fittings. Check that
the fittings are clean.
3. Retract the sleeve on the coupling as illustrated.
4. Insert the plug and release the sleeve as illustrated.
5. Push the plug into the sleeve until the sleeve snaps
forward to lock the plug in the coupling.
6. Open the manual gas shutoff valve.
To Disconnect:
1. Close the manual shutoff valve.
2. Push the sleeve back and gently pull out the plug.
3. Replace the protective rubber caps on the plug and sleeve ends of the quick disconnect couplings.
In the connection process, make sure:
• The gas supply hose does not come in contact or remain in contact with the firebox.
WARNING
17
A1

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dga550ssn-d

Tabla de contenido