TROUBLESHOOTING
PROBLEM
No gas flow or an
obstructed gas flow.
POSSIBLE CAUSE
1. Gas supply shut off.
2. Poor connection between gas
hose plug fitting and sleeve
coupling.
3. Burner inlet blocked.
CORRECTIVE ACTION
1. Check that the manual gas supply
shutoff valve is open.
2. Turn off the grill knobs, close the gas
supply shutoff valve and check the
connection between the plug and
sleeve coupling. Disconnect and
reconnect, if necessary.
3. Clean the burner inlet (venturi) and
burner as described by the Care and
Maintenance section in the manual.