Wb-O2 Meter Nano Electric Installation - FuelTech WB-O2 Nano Manual De Instalación Y Especificaciones Técnicas

Condicionador para sensor lambda de banda ancha
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. WB-O2 Meter Nano Electric Installation

The WB-02 Nano has a 12-way connector with 3 wire groups. One of them has
the connector for the O2 sensor, the second makes the CAN communication
with Power FT ECU's and the third is responsible for power and analog output.
By default, the analog output is set to values of 8.7AFR to 16.2AFR Gas, but
can be configured to 5.14AFR to 17.6AFR Gas or 9.55 to 19.11AFR or 9.55
to 58.80AFR or yet 9.55 to 146.9AFR (Gas), if necessary.
See the following wiring diagram for details about connections.
12-way connector
Wire color
Pin
Red
1
Yellow
2
Brown
3
Red
4
Yellow/Red
5
White/Red
6
Orange
7
Green
8
Blue
9
Black/White
10
Black
11
Yellow/Blue
12
Connection
O2 sensor
O2 sensor pin 6 - IP
O2 sensor
O2 sensor pin 5 - sensor negative signal
O2 sensor
O2 sensor pin1 - Sensor positive signal
Switched 12V The use of a 10A fuse is recommended
0-5V Analog
Analog output proportional to the lambda readings. Used
Output
for connection with data acquisition systems
CAN
CAN (+): connected to Power FT ECU's CAN port
O2 sensor
O2 sensor pin 2 - sensor resistor calibration
O2 sensor
O2 sensor pin 3 - sensor heater positive
O2 sensor
O2 sensor pin 4 - Sensor heater negative signal
Chassis/
Engine ground (head/block)
Engine Power
Do not connect it directly to the battery negative.
Ground
Connected directly to the battery negative with no
Battery's
splices. Do not connected this wire to the chassis
Negative
engine block or head.
CAN
CAN (-): connected to Power FT ECU's CAN port
WB-O
2
OBS
Nano
EN
5