Lambda Readings Analog Outputs; Lambda Analog Output In Volts - 5.14 To 17.6Afr; Lambda Analog Output In Volts - 8.7 To 16.2 Afr (Default); Lambda Analog Output In Volts - 9.6 To 19.1 Afr - FuelTech WB-O2 Nano Manual De Instalación Y Especificaciones Técnicas

Condicionador para sensor lambda de banda ancha
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Lambda Readings analog outputs

7.1 Lambda Analog Output in
Volts – 5.14 to 17.6AFR
AFR
Lambda
Gasolina
0.35
5.14
1.20
17.6
7.2 Lambda Analog Output in
Volts – 8.7 to 16.2 AFR (default)
Lambda
AFR Gas
0.59
8.7
1.10
16.2
7.3 Lambda Analog Output in
Volts – 9.6 to 19.1 AFR
Lambda
AFR Gas
0.65
9.6
1.30
19.1
When there is an output reading error, the analog output locks at 0.00V. Thus,
it is possible to know if there is any problem or error in the equipment. To
configure this output on external equipment, it is necessary to supply the first
and last values of the table above.
AFR
Metanol/
Volts (V)
Etanol
2.3
0.20
7.7
4.80
AFR
Methanol/
Volts (V)
Etanol
3.8
0.20
7.1
4.80
AFR
Methanol/
Volts (V)
Etanol
4.2
0.20
8.3
4.80
7.4 Lambda Analog Output in
Volts – 9.6 to 58.8 AFR
Lambda
AFR Gas
0.65
9.6
4.00
58.8
7.5 Lambda Analog Output in
Volts – 9.6 to 146.9 AFR
Lambda
AFR Gas
0,65
9,6
9,99
149,9
WB-O
Nano
2
AFR
Methanol/
Volts (V)
Etanol
4.2
0.20
25.7
4.80
AFR
Methanol/
Volts (V)
Etanoll
4.2
0.20
64.1
4.80
11
EN

Publicidad

Tabla de contenido
loading

Productos relacionados para FuelTech WB-O2 Nano

Este manual también es adecuado para:

Wbo2 nano