M ODE L UW- 24 | UW- 2 4 F S S I T E P R EPAR AT I O N
Electrical Requirements
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
The electrical outlet must be placed so
IMPORTANT NOTE:
the grounding prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
EL EC T R IC A L R EQ UI R EM ENT S
Electrical Supply
Service
Receptacle
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
LEFT SIDE
OF OPENING
1
2"
15
/
"
2
(51)
(394)
3"
(76)
FLOOR
Electrical supply location
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
Preparation
To operate properly, the door must open a minimum of 90°.
Use a minimum 3"
filler in corner installations to assure
(76)
a 90° door opening.
Uncrate the unit and inspect for damage. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket, hardware, and the leveling legs which hold the
wood base to the bottom of the unit.
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
M O DE L U W-2 4
The anti-tip bracket should be attached to the wall behind
the unit with the bracket flange located
of the unit. Refer to the illustration below. Failure to properly
position the anti-tip bracket will prevent proper engagement.
For installations that cannot accommodate the anti-tip
bracket, a countertop bracket is provided to secure the unit
to the countertop. Refer to the illustration below.
ANTI-TIP
BRACKET
1
/
"
4
(6)
Anti-tip bracket (UW-24)
1
/
"
above the top
(6)
4
COUNTERTOP
BRACKET
Countertop bracket
|
subzero.com
5