WH / WHPP
ABICOR BINZEL control board option for resistance adjustment
For this connection version, the control board and the micro-fuse are installed in the wire feed
unit at a readily accessible location. The required supply voltage is tapped, for example, at the
solenoid valve connection "Shielding gas ON/OFF" or at the "Control contactor". In some
cases, a series resistance for limiting the motor current is required.
1
Motor control
2
Push motor
3
Feed block
4
Feed rollers
Fig. 14
Control board option for resistance adjustment
Pull motor activation option
This connection version allows for a power supply of its own. The following operating options
are possible:
• Wire feed (welding)
• Wire feed (currentless)
• Wire return
1
Motor control
2
Push motor
3
Feed block
Fig. 15
Pull motor activation option
These three functions are activated via robot outputs on the input plug X10, while the pull motor
is connected via the plug X11. For further information, such as connecting diagrams and
specifications, please refer to the operating instructions Pull Motor Activation.
BAL.0014 • 2019-01-16
10
R
R
6
5
9
M
7
8
5
Micro-fuse
6
Pull motor
7
Pull gearbox
8
Wire feed roller
11
6
X11 X10
M
7
8
4
Feed rollers
5
Micro-fuse
6
Pull motor
6 Putting into operation
1
2
M
3
4
9
Control board
For other voltages, a series
transformer is required!
10 Series resistance
1
2
M
3
4
7
Pull gearbox
8
Wire feed roller
9
Pull motor activation
EN - 17