Outputs Page
The parameters for the dialer's two outputs are programmed on this page
To set or cancel options, double-click the appropriate box.
Active state
- The state of the non-operating output is programmed in this box:
= Open-Collector Normally Open.
= Open-Collector Normally Closed.
PSTN fault
- If chosen, the output will be activated in the event of a telephone line failure.
Mains fault
- If chosen, the output will be activated if power is missing for at least 15 minutes.
Low battery
- If chosen, the output will be activated in the event of insufficient battery level.
FTC
- If chosen, the output will be activated if a call is not completed properly.
Call routing
- If chosen, the output will be activated when the dialer performs a phone call.
One way audio
- If chosen, the output will be activated when listen-in is activated.
Remote control
- If chosen, the output will be activated when the user uses remote commands.
Monostab.
- If chosen (marked by the check
length of time (ON Dur.). Once this time is completed the output will return to the non-operating state.
ON Dur. (sec.)
- This box is active only if the Monostab. Option is selected. Specify the monostable time from
1 to 240 seconds by clicking the mouse on the arrow that appears near the number.
Events/Actions Page
Actions the dialer must carry out in response to specific events or actions are programmed on this page.
Telephone numbers
listed in the Description column occur. These telephone numbers are programmed on the Phonebook Page.
To select a number, click the appropriate box. The check sign
been selected.
The Mains fault event occurs only if power is missing for at least 15 minutes.
C-ID
- Telemonitoring Contact ID PINs (3 digits) are programmed in this column.
SIA
- SIA Telemonitoring PINs (2 digits) are programmed in this column.
To set the Telemonitoring PINs, click the appropriate box twice and enter the PIN.
Mess. #
- Up to 3 voice messages can be sent when an event or action listed in the Description column occurs.
To select a message, double-click the appropriate box and choose the message from those available.
Options Page
The options and parameters for correct dialer operation are programmed on this page.
Selection
- Click on the appropriate boxes to disable DTMF tone control, select tone dialing, or select pulse
dialing.
Start playing after
- manner in which a dialer sends a voice message is programmed in this section.
z If Selection, is chosen, the message will be sent after the remote telephone sends a response signal.
z Voice on-line, is chosen, the message will be sent after the remote operator responds.
z Delay, is chosen, the message will be sent after the timed delay, programmable from 0 to 99 seconds. Set
the delay time by clicking the arrow next to the number, or clicking on the box and manually inserting the number
of seconds.
Vocal messages
- The parameters for voice messages are programmed in this section. These parameters
are:
The number of times each message is repeated (minimum 1, maximum 9),
The duration and number of messages as specified in the following:
2 messages = two messages, each 32 seconds long (factory default);
4 messages = four messages, each 16 seconds long;
1 + 4 messages = one 32 second long message and four 8 second long messages;
8 messages = eight messages, each 8 seconds long.
A brief description can be written for each voice message by clicking on the message box.
General options
- The dialer's general options are programmed in this section, described as the following:
z Number of rings - The number of rings after which the dialer answers the phone (if able to do so). If the
installer has enabled the Bypass answering machine option, this option will be ignored.
z Call attempts - Number of times a call will be attempted in the event it is not properly completed.
z Tone on PSTN fail - The dialer normally shows the presence or absence of the phone line on its display.
4 Channel telephone dialler
' ' ' ' '
- Select one or more telephone numbers that the dialer will call when one of the events
symbol), the output will, upon activation, remain active for a set
' ' ' ' '
will indicate that the telephone number has
.
G